Fire Extinguishers: Lifecycle & Expiration

Conner Wolff-Torres · Aug 10, 2022 ·

Fire Extinguisher Expiration

Fire extinguishers don’t last forever, and while all fire extinguishers do expire at some point, there is not always a set expiration date. As your first line of defense during a fire, it is important that your extinguishers are functional and well maintained.

  • Facebook
  • Instagram
  • Twitter
  • LinkedIn
  • Pinterest
  • TikTok
  • YouTube

How Long Do Fire Extinguishers Last?

Do fire extinguishers expire? All fire extinguishers should be installed, inspected and maintained in accordance with the National Fire Protection Association standard titled “Portable Fire Extinguishers“, NFPA-10 and the requirements of local authorities having jurisdiction.

Fire Extinguisher Manufacture Date

The lifespan of a fire extinguisher varies based on a few factors including:

  • Type of fire extinguisher
  • Whether the extinguisher is disposable or rechargeable
  • How well the extinguisher is maintained
  • The date it was manufactured
  • Manufacturer recommendations

When to Replace Your Fire Extinguisher

According to NFPA standards, disposable fire extinguishers need to be replaced every 12 years and rechargeable fire extinguishers must be recharged every 6 years. 

Some manufacturers set recommended expiration dates for their fire extinguishers. However, there are many extinguishers without expiration dates which can make it hard to tell when it should be replaced. 

In short, fire extinguishers expire. Certain types of fire extinguishers are now considered obsolete as regulations change or technology advances. NFPA guidelines dictate which types of extinguishers should be removed from service. If you have an older fire extinguisher, one of our experienced technicians can help you to determine whether it needs to be replaced.

Do Fire Extinguishers Expire?

Monthly Extinguisher Inspection

Occupational Safety and Health Administration (OSHA) regulations mandate that commercial businesses must inspect their portable fire extinguishers monthly. Sometimes referred to as a visual inspection, monthly inspections can be executed by employees who have received proper training. Every month, you should complete a visual check of your fire extinguishers to make sure that they are still functional in the following areas – 

Location & Accessibility

All portable fire extinguishers should be unobstructed, easy to see, and easy to reach. If the extinguisher is blocked or unreachable, any obstructions should be moved or the extinguisher itself should be relocated where it will be more accessible. 

Low Pressure Fire Extinguisher Gage: Do Fire Extinguishers Expire
Low Pressure Gauge Reading

Gauge Pressure Reading

A disposable fire extinguisher has a plastic head with a gauge that reads “full” or “empty”. Rechargeable extinguishers have a metal head with a gauge that shows the level of charge.

For a rechargeable extinguisher, the needle of the pressure gauge should be pointing to the green indicator, known as the operating zone. If the needle is below the operating zone, the extinguisher has lost pressure and needs to be recharged by a professional. If the needle is above the operating zone, it has too much pressure and is at risk of a leak or a cylinder failure (read: explosion). Call us right away if the pressure gauge is outside of the operating zone in either direction for service.

Inspection Tag: Do Fire Extinguishers Expire
Inspection Tag Example: Front and Back

Inspection Tag

Check the inspection tag to see when the last annual inspection took place. If your inspection date is getting close, make a note to call and schedule this year’s maintenance and inspection. If there is no tag, the extinguisher should be inspected to avoid any issues. After your inspection is complete, our technician will attach an updated inspection tag punched with the month, year, the type of extinguisher and the service performed.

Corrosion: Do Fire Extinguishers Expire
Corroded Fire Extinguisher

Visual Damage

Additionally, the exterior of the extinguisher needs to be checked thoroughly for damage or corrosion. Check that the instruction label is present and easy to read. The serial number should also be legible. Look for dents and punctures, as well as paint removal and rust. The hose should be unobstructed, securely fastened to the side of the extinguisher and free of cracks or other damage. Tamper seals are required and indicate if anyone has attempted to use or discharge the unit. Tamper seals are placed around the locking pin and secured around the handle. They may look similar to a zip tie, but they break easily with a little bit of force. You cannot secure an extinguisher with a zip tie!  If any extinguishers are damaged or tampered with, have them inspected immediately.

Document Your Findings

Finally, most inspection tags provided space to record monthly inspections; sign your name or initials and date of inspection to confirm that it has been done. After you’ve completed your inspection and signed off, write a report detailing any issues and whether any actions have been taken to remedy them. Your report should include your name, date, and location of the extinguisher that needs service.

Internal Fire Extinguisher Components: Do Fire Extinguishers Expire
Internal Extinguisher Components

Regular Maintenance 

Regular inspections, testing, and maintenance according to NFPA and manufacturer recommendations can help to extend the lifespan of your fire extinguishers. Hiring the experienced professionals at A P Fire can help to keep your extinguishers functional and code compliant. 

Annual Inspections

Fire Extinguisher Inspection
Annual Inspection

While on site, our annual inspection of fire extinguishers shall include a check of at least the following items: 

1. Location in designated place. 

2. No obstruction to access or visibility. 

3. Pressure gauge reading or indicator in the operable range or position. 

4. Fullness determined by weighing or hefting for self-expelling-type extinguishers, Cartridge-operated extinguishers, and pump tanks. 

5. Operating instructions on nameplate and facing outward. 

6. Safety seals and tamper indicators not broken or missing. 

7. Examination for obvious physical damage, corrosion, leakage, or clogged nozzle

Maintenance on Expired Fire Extinguishers

Six & Twelve Year Maintenance

Every six years, additional testing is required to ensure your extinguisher is in optimal operating condition. At this stage of maintenance, the unit must be completely dismantled so inspections can be completed on all internal components including a check of at least the following items:

1. Discharge chemical and pressure into a “closed” dry chemical recovery system making sure that the extinguisher is completely empty and depressurized. 

2. Clean extinguisher to remove dirt, grease or foreign material. Check to make sure that the instruction nameplate is securely fastened and legible. Inspect the cylinder for corrosion, abrasion, dents or weld damage. 

3. Inspect the extinguisher for damaged, missing or substitute parts. Only factory replacement parts are approved for use. 

4. Check the date of manufacture on the extinguisher label.

5. (12 year only) Hydrostatically test to factory test pressure marked on the label, using the proof pressure method, in accordance with CGA C-1 and NFPA 10. 

6. Visually inspect the pressure gauge – if bent, damaged or improper type or pressure – replace. 

7. Check ring pin for freedom of movement. Replace if bent or if removal appears difficult. 

8. Inspect discharge lever for any dirt or corrosion which might impair freedom of movement. Inspect carrying handle for proper installation. If lever, handle or rivets are damaged, replace. 

9. Remove nozzle or hose and horn assembly and visually inspect threads on nozzle or hose coupling, horn and hose for damage, and replace as necessary. Blow air through nozzle or hose and horn to ensure passage is clear of foreign material. 

10. Inspect the valve assembly for corrosion or damage to nozzle or hose thread connection. Replace valve assembly or component parts as necessary. 

11. Remove and disassemble valve assembly by removing downtube, spring and valve stem assembly. Install a new valve stem and collar o-ring after lightly lubricating. 

 12. Recharge the extinguisher.

13. Complete maintenance by issuing a new inspection tag and service collar.

We perform annual inspections, six year maintenance, twelve year hydrostatic testing and we will recharge your extinguisher in the event it has been discharged. As of 2022, we are distributors for Amerex and Badger brand extinguishers. We service school districts, healthcare facilities, municipalities and other commercial buildings. If you have a small business or home extinguisher, we also accept walk-ins at our office location. In the end, there is no hard and fast rule of when fire extinguishers expire. If you are worried about your fire extinguishers expiring and would like to request service for your fire extinguishers, contact us!

Fire Extinguisher Service request
A P Fire Protection Extinguisher
A P Fire Protection Shield Full Color Logo
  • Facebook
  • Instagram
  • Twitter
  • LinkedIn
  • Pinterest
  • TikTok
  • YouTube

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

  1. Afton Jackson on Fire Extinguishers: Lifecycle & ExpirationJanuary 6, 2023

    With how important fire extinguishers are to the safety of employees, inspecting them every year definitely does feel like an…

  2. Подготовка к осенне-зимнему периоду в Минске on ASBA 2022: Another Great YearJanuary 5, 2023

    I do not even know how I ended up here, but I thought this post was good. I do not…

  3. Подготовка к ОЗП on ASBA 2022: Another Great YearJanuary 5, 2023

    It’s hard to come by knowledgeable people for this subject, but you seem like you know what you’re talking about!…

  4. опрессовка системы теплоснабжения on Fire Protection for Schools & UniversitiesDecember 16, 2022

    An impressive share! I have just forwarded this onto a friend who was conducting a little homework on this. And…

  5. tracfone special coupon 2022 on Authority Having Jurisdiction (AHJ) and Fire ProtectionDecember 3, 2022

    Hey! Would you mind if I share your blog with my twitter group? There’s a lot of folks that I…

What Does A P Fire Protection Do?

Molly Smith · Aug 7, 2020 ·

We do it all!!

A P Fire Protection is dedicated and passionate about protecting your property and employees. We test, inspect, install and repair all related devices including but not limited to fire alarm systems, fire sprinkler suppression systems, fire extinguishers and backflows. In an ideal situation, you make one call to fix all of your fire protection needs. Not calling three separate companies, or even two, just one call and A P Fire Protection will do it all! We are committed to excellence while aggressively growing and maintaining the relationships we have fostered with our customers over the years.

1. Fire Sprinkler Suppression Systems

Fire Sprinkler Suppression System

The main job of the sprinkler suppression system is to slow the spread of a fire, allowing ample time for emergency responders to arrive. They are designed to react automatically in the event of a fire which allows for safe egress of anyone around. For the most part, inspections of your sprinkler system should happen annually. However, depending on the type of system you have, the frequency of your inspections could increase. For that reason, it is important to know exactly what type of system you have and what your local AHJ (Authority Having Jurisdiction) requires. If you are unaware then an A P Fire Protection employee would gladly walk your property and provide you with a free estimate.

Schedule a free walkthrough

2. Fire Alarm Systems

Fire Alarms are so important because they provide prompt warning when a fire breaks out. If the building is occupied then the notifying devices will sound off, telling occupants to leave immediately. If there is nobody in the building and the alarm activates then the monitoring company will notify the appropriate people in a timely manner, including emergency responders. If a system or its connected devices are not properly maintained then it can result in unwanted, ‘annoying’ beeping coming from the panel. This can result in a negative response from the occupants and even diminish the effectiveness of the alarm when it is actually triggered. Any beeping from your panel means your fire alarm systems needs attention – do not put this off! The ability to detect a fire early is the difference between losing everything and keeping the damage to a minimum!

Watch to learn more about Panels
watch to learn more about initiating devices
Watch to learn more about notifying devices

3. Kitchen Hood Suppression System

Often times a kitchen is the heartbeat of a restaurant, but where there are high heats and grease there are also big risks for fire. A fire needs three things to flourish – heat, oxygen and fuel. The purpose of the suppression system is to starve the fire of its oxygen by smothering the flames with a wet chemical. As soon as the nozzles inside the kitchen hood exhaust detects a fire the gas line/electrical power automatically shuts off which deprives the fire of its fuel source as well. Kitchen Hoods need to be serviced semi-annually because if the grease build up gets too extensive then it will effect the performance of the fusible links, which need to pop in order to release the agent.

4. Fire Extinguishers

Although often times overlooked or forgotten in the corner of a room, fire extinguishers are a necessity when it comes to work place safety. They can be the difference between a small, localized fire and an incident that now requires the fire department. Similar to a sprinkler system, fire extinguishers are meant to assist employees in controlling the spread of a fire for a safe escape while emergency responders are deployed. Equally important to knowing how to use a fire extinguisher, is knowing which one to use for certain fires. There are multiple different classes of fires that all require specific extinguishers. Quick overview:

Class A – Ordinary Combustibles (wood and paper)
Class B – Flammable Liquids (gas, grease, oil and alcohol)
Class C – Electrical Equipment (computers, servers, motors and appliances)
Class D – Flammable Metals

If you don’t know how to properly use a fire extinguisher, schedule a training session with A P Fire Protection! Our team is ready to provide you with the highest quality training and services.

Fire Extinguisher Training

5. Backflows

A P Fire Protection
7612 N 71st Ave
Glendale, AZ 85303

License Numbers: CR-67 # ROC 251920, C-16 ROC 251919